This application uses an adiabatic model, which factors in the increased internal temperature generated by friction. The temperature increase due to friction causes higher pressure rise. Taking these real-world values into account during tool design can prevent unexpected challenges when the products are used in high production environments. For general reference, DADCO’s standard product catalogs use an isothermal model, which assumes no change in temperature during use, this matches the Industry Standard used in the nitrogen gas spring industry.